Testing MikroTik Ethernet Rx & Tx lines for overvoltage

On a properly functioning router, such as the MikroTik hAP (RB951Ui-2nD), the electrical resistance between the Ethernet lines «Rx» and «Tx» should be 150 ohms ±4%.

Otherwise, the Ethernet port (RJ-45) on the router being tested may have been damaged due to a static overvoltage.

  • checking Rx-Tx lines ethernet MikroTik
  • terminating resistors
  • galvanic separation lines Ethernet
  • Tx lines for transmission, Rx for receptions

Description of Ethernet Rx and Tx line contacts

Contacts 1 and 2 (white-orange, orange) are used for transmitting (Tx) information (signals), while contacts 3 and 6 (white-green, green) are used for receiving (Rx). The 150 ohm value is made up of two 75 ohm «terminal» resistors. Terminating resistors - are present in almost all network devices that have an Ethernet (RJ-45) port to suppress common-mode interference.